HEIDENHAIN iTNC 530 (340 49x-05) Cycle programming User Manual

Page 368

Advertising
background image

368

Touch Probe Cycles: Automatic Datum Setting

15.1

0

D

A

TUM CIR

C

LE CENTER (Cy

c

le

416, DIN/ISO: G416)

U

Probe in TS axis

Q381: Specify whether the TNC

should also set the datum in the touch probe axis:
0: Do not set datum in the touch probe axis
1: Set datum in the touch probe axis

U

Probe TS axis: Coord. 1st axis

Q382 (absolute):

Coordinate of the probe point in the reference axis of
the working plane at which point the datum is to be
set in the touch probe axis. Only effective if Q381 =
1. Input range -99999.9999 to 99999.9999

U

Probe TS axis: Coord. 2nd axis

Q383 (absolute):

Coordinate of the probe point in the minor axis of the
working plane at which point the datum is to be set in
the touch probe axis. Only effective if Q381 = 1. Input
range -99999.9999 to 99999.9999

U

Probe TS axis: Coord. 3rd axis

Q384 (absolute):

Coordinate of the probe point in the touch probe axis
at which point the datum is to be set in the touch
probe axis. Only effective if Q381 = 1. Input range
-99999.9999 to 99999.9999

U

New datum in TS axis

Q333 (absolute): Coordinate in

the touch probe axis at which the TNC should set the
datum. Default setting = 0. Input range: -99999.9999
to 99999.9999

U

Setup clearance

Q320 (incremental): Additional

distance between measuring point and ball tip. Q320
is added to MP6140, and is only effective when the
datum is probed in the touch probe axis. Input range
0 to 99999.9999, alternatively PREDEF

Example: NC blocks

5 TCH PROBE 416 DATUM CIRCLE CENTER

Q273=+50

;CENTER IN 1ST AXIS

Q274=+50

;CENTER IN 2ND AXIS

Q262=90

;NOMINAL DIAMETER

Q291=+34

;ANGLE OF 1ST HOLE

Q292=+70

;ANGLE OF 2ND HOLE

Q293=+210 ;ANGLE OF 3RD HOLE

Q261=-5

;MEASURING HEIGHT

Q260=+20

;CLEARANCE HEIGHT

Q305=12

;NO. IN TABLE

Q331=+0

;DATUM

Q332=+0

;DATUM

Q303=+1

;MEAS. VALUE TRANSFER

Q381=1

;PROBE IN TS AXIS

Q382=+85

;1ST CO. FOR TS AXIS

Q383=+50

;2ND CO. FOR TS AXIS

Q384=+0

;3RD CO. FOR TS AXIS

Q333=+1

;DATUM

Q320=0

;SETUP CLEARANCE

Advertising