3 calibrate ts length (cycle 9), Cycle run, Cycle parameters – HEIDENHAIN iTNC 530 (340 49x-05) Cycle programming User Manual

Page 436

Advertising
background image

436

Touch Probe Cycles: Special Functions

1

7.3 CALIBRA

TE TS LENGTH (Cy

c

le

9)

17.3 CALIBRATE TS LENGTH

(Cycle 9)

Cycle run

Touch probe cycle 9 automatically calibrates the length of a touch
trigger probe at a point that you determine.

1

Pre-position the touch probe so that the coordinate defined in the
cycle can be accessed without collision.

2

The TNC moves the touch probe in the direction of the negative
tool axis until a trigger signal is released.

3

Finally, the TNC moves the touch probe back to the starting point
of the probing process and writes the effective touch probe length
into the calibration data.

Cycle parameters

U

Coordinate of datum

(absolute): Exact coordinate of

the point that is to be probed. Input range: -
99999.9999 to 99999.9999

U

Reference system? (0=ACT/1=REF):

Specify the

coordinate system on which the entered datum is to
be based:
0: Entered datum is based on the active workpiece
coordinate system (ACT system)
1: Entered datum is based on the active machine
coordinate system (REF system)

Example: NC blocks

5 L X-235 Y+356 R0 FMAX

6 TCH PROBE 9.0 CALIBRATE TS LENGTH

7 TCH PROBE 9.1 DATUM +50 REFERENCE
SYSTEM 0