Using Touch Probe Cycles

13.1 Gener

a

l Inf

o

rm

ation about T

ouc

h Pr

obe Cy

cles

13.1 General Information about

Touch Probe Cycles

Method of function

Whenever the TNC runs a touch probe cycle, the 3-D touch probe
approaches the workpiece in one linear axis. This is also true during an
active basic rotation or with a tilted working plane. The machine tool
builder determines the probing feed rate in a machine parameter (see
“Before You Start Working with Touch Probe Cycles” later in this
chapter).

When the probe stylus contacts the workpiece,

„

the 3-D touch probe transmits a signal to the TNC: the coordinates
of the probed position are stored,

„

the touch probe stops moving, and

„

returns to its starting position at rapid traverse.

If the stylus is not deflected within a distance defined in MP 6130, the
TNC displays an error message.

The TNC must be specially prepared by the machine tool
builder for the use of a 3-D touch probe. The machine tool
manual provides further information.

If you are carrying out measurements during program run,
be sure that the tool data (length, radius) can be used from
the calibrated data or from the last TOOL CALL block
(selected with MP7411).