Touch Probe Cycles: Automatic Datum Setting

15.13 D

A

TUM IN ONE AXIS (C

y

c

le

41

9, DIN/ISO: G41

9

)

Cycle parameters

U

1st meas. point 1st axis

Q263 (absolute):

Coordinate of the first touch point in the reference
axis of the working plane. Input range: -99999.9999 to
99999.9999

U

1st meas. point 2nd axis

Q264 (absolute):

Coordinate of the first touch point in the minor axis of
the working plane. Input range: -99999.9999 to
99999.9999

U

Measuring height in the touch probe axis

Q261

(absolute): Coordinate of the ball tip center (= touch
point) in the touch probe axis in which the
measurement is to be made. Input range:
-99999.9999 to 99999.9999

U

Setup clearance

Q320 (incremental): Additional

distance between measuring point and ball tip. Q320
is added to MP6140. Input range 0 to 99999.9999,
alternatively PREDEF

U

Clearance height

Q260 (absolute): Coordinate in the

touch probe axis at which no collision between touch
probe and workpiece (fixtures) can occur. Input range
-99999.9999 to 99999.9999, alternatively PREDEF

U

Measuring axis (1...3: 1=reference axis)

Q272:

Axis in which the measurement is to be made:
1: Reference axis = measuring axis
2: Minor axis = measuring axis
3: Touch probe axis = measuring axis

X

Y

Q264

Q263

+

–

–

+

Q267

Q272=2

Q272=1

MP6140 + Q320

1

X

Z

Q260

Q261

+

–

Q272=1

Q272=3

Q267

1

Axis assignment

Active touch probe
axis: Q272= 3

Corresponding
reference axis:
Q272 = 1

Corresponding
minor axis:
Q272 = 2

Z

X

Y

Y

Z

X

X

Y

Z

Advertising