Notes on various calibration methods

„

Rough optimization during commissioning after entering
approximate dimensions.

„

Number of measuring points between 1 and 2

„

Angular step of the rotary axes: Approx. 90°

„

Fine optimization over the entire range of traverse

„

Number of measuring points between 3 and 6

„

The start and end angles should cover the largest possible
traverse range of the rotary axes

„

Position the calibrating ball on the machine table so that on rotary
table axes there is a large measuring circle, or so that on swivel
head axes the measurement can be made at a representative
position (e.g. in the center of the traverse range).

„

Optimization of a specific rotary axis position

„

Number of measuring points between 2 and 3

„

The measurements are made near the rotary axis angle at which
the workpiece is to be machined

„

Position the calibration ball on the machine table for calibration at
the position subsequently intended for machining

„

Inspecting the machine accuracy

„

Number of measuring points between 4 and 8

„

The start and end angles should cover the largest possible
traverse range of the rotary axes

„

Determining the rotary axis backlash during inspection

„

Number of measuring points between 8 and 12

„

The start and end angles should cover the largest possible
traverse range of the rotary axes