HEIDENHAIN iTNC 530 (340 49x-05) Cycle programming User Manual

Page 427

Advertising
background image

HEIDENHAIN iTNC 530

427

16.13 MEA

S

URE PLANE (Cy

c

le 431, DIN/ISO: G431)

U

Setup clearance

Q320 (incremental): Additional

distance between measuring point and ball tip. Q320
is added to MP6140. Input range 0 to 99999.9999,
alternatively PREDEF

U

Clearance height

Q260 (absolute): Coordinate in the

touch probe axis at which no collision between touch
probe and workpiece (fixtures) can occur. Input range
-99999.9999 to 99999.9999, alternatively PREDEF

U

Measuring log

Q281: Definition of whether the TNC is

to create a measuring log:
0: No measuring log
1: Generate measuring log: with the standard setting
the TNC saves the log file TCHPR431.TXT in the
directory in which your measuring program is also
stored.
2: Interrupt the program run and display the
measuring log on the screen. Resume program run
with NC Start.

Example: NC blocks

5 TCH PROBE 431 MEASURE PLANE

Q263=+20

;1ST POINT 1ST AXIS

Q264=+20

;1ST POINT 2ND AXIS

Q294=-10

;1ST POINT 3RD AXIS

Q265=+50

;2ND POINT 1ST AXIS

Q266=+80

;2ND POINT 2ND AXIS

Q295=+0

;2ND POINT 3RD AXIS

Q296=+90

;3RD POINT 1ST AXIS

Q297=+35

;3RD POINT 2ND AXIS

Q298=+12

;3RD POINT 3RD AXIS

Q320=0

;SETUP CLEARANCE

Q260=+5

;CLEARANCE HEIGHT

Q281=1

;MEASURING LOG

Advertising