Touch Probe Cycles: Automatic Kinematics Measurement

1

8

.4 MEA

S

URE KINEMA

TICS (Cy

c

le

451, DIN/ISO: G451; option)

Positioning direction

The positioning direction of the rotary axis to be measured is
determined from the start angle and the end angle that you define in
the cycle. A reference measurement is automatically performed at 0°.
The TNC will issue an error message if the selected start angle, end
angle and number of measuring points result in a measuring position
of 0°.

Specify the start and end angles to ensure that the same position is
not measured twice. As mentioned above, a duplicated point
measurement (e.g. measuring positions +90° und -270°) is not
advisable, however it does not cause an error message.

„

Example: start angle = +90°, end angle = –90°

„

Start angle = +90°

„

End angle = –90°

„

No. of measuring points = 4

„

Angle step resulting from the calculation = (–90 - +90) / (4-1) = –
60°

„

Measuring point 1= +90°

„

Measuring point 2= +30°

„

Measuring point 3= -30°

„

Measuring point 4= –90°

„

Example: start angle = +90°, end angle = +270°

„

Start angle = +90°

„

End angle = +270°

„

No. of measuring points = 4

„

Angle step resulting from the calculation = (270 - 90) / (4-1) = +60°

„

Measuring point 1= +90°

„

Measuring point 2= +150°

„

Measuring point 3= +210°

„

Measuring point 4= +270°