Cycle parameters, 5 mea s uring in 3-d (cy c le 4, fcl 3 function) – HEIDENHAIN iTNC 530 (340 49x-05) Cycle programming User Manual

Page 440

Advertising
background image

440

Touch Probe Cycles: Special Functions

1

7.5 MEA

S

URING IN 3-D (Cy

c

le 4, FCL 3 function)

Cycle parameters

U

Parameter number for result:

Enter the number of

the Q parameter to which you want the TNC to assign
the first coordinate (X). Input range: 0 to 1999

U

Relative measuring path in X:

X component of the

direction vector defining the direction in which the
touch probe is to move. Input range: -99999.9999 to
99999.9999

U

Relative measuring path in Y:

Y component of the

direction vector defining the direction in which the
touch probe is to move. Input range: -99999.9999 to
99999.9999

U

Relative measuring path in Z:

Z component of the

direction vector defining the direction in which the
touch probe is to move. Input range: -99999.9999 to
99999.9999

U

Maximum measuring path:

Enter the maximum

distance from the starting point by which the touch
probe may move along the direction vector. Input
range: -99999.9999 to 99999.9999

U

Feed rate for measurement

: Enter the measuring

feed rate in mm/min. Input range: 0 to 3000.000

U

Maximum retraction path:

Traverse path in the

direction opposite the probing direction, after the
stylus was deflected. Input range: 0 to 99999.9999

U

Reference system? (0=ACT/1=REF)

: Specify whether

the result of measurement is to be saved in the actual
coordinate system (IST, can therefore be shifted or
rotated), or with respect to the machine coordinate
system (REF).
0: Save the measurement result in the ACT system
1: Save the measurement result in the REF system

Example: NC blocks

5 TCH PROBE 4.0 MEASURING IN 3-D

6 TCH PROBE 4.1 Q1

7 TCH PROBE 4.2 IX-0.5 IY-1 IZ-1

8 TCH PROBE
4.3 DIST +45 F100 MB50 REFERENCE SYSTEM:0

Advertising