Touch Probe Cycles: Special Functions

1

7.4 MEA

S

URING (Cy

c

le 3)

Cycle parameters

U

Parameter number for result:

Enter the number of

the Q parameter to which you want the TNC to assign
the first measured coordinate (X). The values Y and Z
are in the immediately following Q parameters. Input
range: 0 to 1999

U

Probing angle:

Enter the angle in whose direction the

probe is to move and confirm with the ENT key. Input
range: X, Y or Z

U

Probing angle:

Angle, measured from the probing

axis

at which the touch probe is to move. Confirm

with ENT. Input range: -180.0000 to 180.0000

U

Maximum measuring path:

Enter the maximum

distance from the starting point by which the touch
probe is to move. Confirm with ENT. Input range: -
99999.9999 to 99999.9999

U

Feed rate for measurement

: Enter the measuring

feed rate in mm/min. Input range: 0 to 3000.000

U

Maximum retraction path:

Traverse path in the

direction opposite the probing direction, after the
stylus was deflected. The TNC returns the touch
probe to a point no farther than the starting point, so
that there can be no collision. Input range: 0 to
99999.9999

U

Reference system? (0=ACT/1=REF)

: Specify whether

the probing direction and the result of measurement
are to be referenced to the actual coordinate system
(ACT, can be shifted or rotated), or to the machine
coordinate system (REF):
0: Probe in the current system and save
measurement result in the ACT system
1: Probe in the machine-based REF system and save
measurement result in the REF system

U

Error mode (0=OFF/1=ON):

Specify whether the TNC

is to issue an error message if the stylus is deflected
at cycle start. If you select mode 1, the TNC saves
the value 2.0 in the 4th result parameter and
continues the cycle.

U

Error mode (0=OFF/1=ON):

Specify whether the TNC

is to issue an error message if the stylus is deflected
at cycle start. If you select mode 1, the TNC saves
the value 2.0 in the 4th result parameter and
continues the cycle:
0: Issue error message
1: Do not issue error message

Example: NC blocks

4 TCH PROBE 3.0 MEASURING

5 TCH PROBE 3.1 Q1

6 TCH PROBE 3.2 X ANGLE: +15

7 TCH PROBE 3.3 DIST +10 F100 MB1

REFERENCE SYSTEM:0

8 TCH PROBE 3.4 ERRORMODE1

Advertising