Cycle parameters – HEIDENHAIN iTNC 530 (340 49x-05) Cycle programming User Manual

Page 370

Advertising
background image

370

Touch Probe Cycles: Automatic Datum Setting

15.1

1

D

A

TUM IN T

O

UCH PR

OBE AXIS (Cy

c

le 41

7,

DIN/ISO: G41

7

)

Cycle parameters

U

1st meas. point 1st axis

Q263 (absolute):

Coordinate of the first touch point in the reference
axis of the working plane. Input range: -99999.9999 to
99999.9999

U

1st meas. point 2nd axis

Q264 (absolute):

Coordinate of the first touch point in the minor axis of
the working plane. Input range: -99999.9999 to
99999.9999

U

1st meas. point 3rd axis

Q294 (absolute):

Coordinate of the first touch point in the touch probe
axis. Input range: -99999.9999 to 99999.9999

U

Setup clearance

Q320 (incremental): Additional

distance between measuring point and ball tip. Q320
is added to MP6140. Input range 0 to 99999.9999,
alternatively PREDEF

U

Clearance height

Q260 (absolute): Coordinate in the

touch probe axis at which no collision between touch
probe and workpiece (fixtures) can occur. Input range
-99999,9999 to 99999.9999, alternatively PREDEF

U

Datum number in table

Q305: Enter the number in the

datum or preset table in which the TNC is to save the
coordinate. If you enter Q305=0, the TNC
automatically sets the display so that the new datum
is on the probed surface. Input range: 0 to 2999

U

New datum in TS axis

Q333 (absolute): Coordinate in

the touch probe axis at which the TNC should set the
datum. Default setting = 0. Input range: -99999.9999
to 99999.9999

U

Measured-value transfer (0, 1)

Q303: Specify

whether the determined datum is to be saved in the
datum table or in the preset table:
-1: Do not use. Is entered by the TNC when old
programs are read in (see “Saving the calculated
datum” on page 332).
0: Write determined datum in the active datum table.
The reference system is the active workpiece
coordinate system.
1: Write determined datum in the preset table. The
reference system is the machine coordinate system
(REF system).

Example: NC blocks

5 TCH PROBE 417 DATUM IN TS AXIS

Q263=+25

;1ST POINT 1ST AXIS

Q264=+25

;1ST POINT 2ND AXIS

Q294=+25

;1ST POINT 3RD AXIS

Q320=0

;SETUP CLEARANCE

Q260=+50

;CLEARANCE HEIGHT

Q305=0

;NO. IN TABLE

Q333=+0

;DATUM

Q303=+1

;MEAS. VALUE TRANSFER

X

Y

Q264

Q263

1

X

Z

Q260

Q294

MP61

40

+

Q320

1

Advertising