1

8

.4 MEA

S

URE KINEMA

TICS (Cy

c

le

451, DIN/ISO: G451; option)

U

Start angle C axis

Q419 (absolute): Starting angle in

the C axis at which the first measurement is to be
made. Input range: –359.999 to 359.999

U

End angle C axis

Q420 (absolute): Ending angle in the

C axis at which the last measurement is to be made.
Input range: –359.999 to 359.999

U

Angle of incid. in C axis

Q421: Angle of incidence

in the C axis at which the other rotary axes are to be
measured. Input range: –359.999 to 359.999

U

Number meas. points C axis

Q422: Number of probe

measurements with which the TNC is to measure the
C axis. If input value = 0, the TNC does not measure
the respective axis. Input range 0 to 12.

U

No. of measuring points (4/3)

Q423: Specify

whether the TNC should measure the calibration ball
in the plane with 4 or 3 probing points. 3 probing
points increase the measuring speed:
4: Use 4 measuring points (standard setting)
3: Use 3 measuring points

U

Preset (0/1/2/3)

Q431: Specify whether the TNC is

to set the active preset (reference point)
automatically in the ball center:
0: Do not set the preset automatically in the ball
center: Set the preset manually before the start of the
cycle
1: Set the preset automatically in the ball center
before measurement: Preposition the touch probe
manually over the calibration ball before the start of
the cycle
2: Set the preset automatically in the ball center after
measurement: Set the preset manually before the
start of the cycle
3: Set the preset in the ball center before and after
measurement: Preposition the touch probe manually
over the calibration ball before the start of the cycle

If you have activated "Preset" before measurement (Q431
= 1/3), then move the touch probe to a position above the
center of the calibration ball before the start of the cycle.