Touch Probe Cycles: Automatic Kinematics Measurement

1

8

.5 PRESET COMPENSA

TION (Cy

c

le 452, DIN/ISO: G452, option)

U

Start angle A axis

Q411 (absolute): Starting angle in

the A axis at which the first measurement is to be
made. Input range: -359.999 to 359.999

U

End angle A axis

Q412 (absolute): Ending angle in the

A axis at which the last measurement is to be made.
Input range: -359.999 to 359.999

U

Angle of incid. A axis

Q413: Angle of incidence in

the A axis at which the other rotary axes are to be
measured. Input range: -359.999 to 359.999

U

Number meas. points A axis

Q414: Number of probe

measurements with which the TNC is to measure the
A axis. If input value = 0, the TNC does not measure
the respective axis. Input range: 0 to 12

U

Start angle B axis

Q415 (absolute): Starting angle in

the B axis at which the first measurement is to be
made. Input range: -359.999 to 359.999

U

End angle B axis

Q416 (absolute): Ending angle in the

B axis at which the last measurement is to be made.
Input range: -359.999 to 359.999

U

Angle of incid. in B axis

Q417: Angle of incidence

in the B axis at which the other rotary axes are to be
measured. Input range: -359.999 to 359.999

U

Number meas. points B axis

Q418: Number of probe

measurements with which the TNC is to measure the
B axis. If input value = 0, the TNC does not measure
the respective axis. Input range: 0 to 12

U

Start angle C axis

Q419 (absolute): Starting angle in

the C axis at which the first measurement is to be
made. Input range: -359.999 to 359.999

U

End angle C axis

Q420 (absolute): Ending angle in the

C axis at which the last measurement is to be made.
Input range: -359.999 to 359.999

U

Angle of incid. in C axis

Q421: Angle of incidence

in the C axis at which the other rotary axes are to be
measured. Input range: -359.999 to 359.999

U

Number meas. points C axis

Q422: Number of probe

measurements with which the TNC is to measure the
C axis. If input value = 0, the TNC does not measure
the respective axis. Input range: 0 to 12

U

No. of measuring points (4/3)

Q423: Specify

whether the TNC should measure the calibration ball
in the plane with 4 or 3 probing points. 3 probing
points increase the measuring speed:
4: Use 4 measuring points (standard setting)
3: Use 3 measuring points

Advertising