5-54

Continued

B.

Energy Saving Search Operation

In energy saving control mode, the maximum applicable voltage is calculated using the output
power. However, a temperature change will change the fixed constants and the maximum applicable
voltage may not be obtained.

n144: Voltage limit of tuning

Limits the range where the voltage can be controlled. Search operation is disabled when

n144 is set

to

0.

n145: Step Voltage of tuning to 100 % output voltage

n146: Step voltage of tuning to 5 % output voltage

n143: Time of average KW

Parameter

n145 & n146 sets the voltage fluctuation for one cycle of the search operation.

Increasing the values will also increase the fluctuation of the rotation speed. The value calculated by
linear interpolation is set for voltages other than above.

Factory Setting:

1 (x24)

Range: 1 to 200 (x24)

Factory Setting:

.2%

Range: 0.1 or 10%

Factory Setting:

.5%

Range: 0.1 or 10%

Factory Setting:

0%

Range: 0 or 100%

5.31 ENERGY SAVING CONTROL

Advertising