26 torque compensation, Torque compensation -37 – Yaskawa V7 Drives User Manual

Page 91

Advertising
background image

5-39

n103 : Torque Compensation Gain (K

T

)

Factory setting:

1.0

Range: 0.0 to 2.5

Torque Compensation Gain (

n103) adjusts how

much the output voltage is boosted when motor
load increases. It is used to compensate for
resistive losses in the motor and the wiring
between the drive and the motor.

n104 : Torque Compensation Time Constant

Factory setting: See Table A3-2

Range: 0.0 to 2.5 (sec)

This parameter adjusts a time delay for the torque compensation gain. Increase to add torque
stability, decrease to improve torque response.

n105 : Torque Compensation Iron Loss

Factory setting: See Table A3-1

Range: 0.0 to 6550 W

This parameter should be adjusted only when motor capacity and drive capacity are different.

n109 : Torque Compensation Limit

Factory setting: 150%

Range: 0 - 250%

This parameter sets the upper voltage limit used by torque compensation.

Except for the most demanding of high starting torque applications, the factory settings of these
parameters will be adequate. The factory settings are set up to match the performance of typical
AC motors.

OUTPUT FREQUENCY

( HZ )

OUTPUT VOLTAGE

( VAC )

460

345

230

115

14 V

0

0

1.5 HZ

30

60

PROGRAMMED V/F PATTERN

(NO LOAD)

AUTO TORQUE BOOST

V/F PATTERN

Example of Torque Compensation

Operation

5.26 TORQUE COMPENSATION

Advertising
This manual is related to the following products: