12 jog reference, Jog reference -13 – Yaskawa V7 Drives User Manual

Page 65

Advertising
background image

5-13

n032 : Jog Reference

Factory setting:

6.00 Hz

Range: 0.00 to 400.0 Hz

n050 thru n056 : Multi-function Inputs

Data

10 : Jog Selection

(Term. S1 - S7)

When jog operation is selected (by external Jog and Run signals), the Drive output will ramp to the
output level set by this parameter.

When an external Jog signal is present, it will override the existing operation mode and the Drive
will ramp to the level set by this parameter.

EXAMPLE:

OPERATION BY REMOTE SIGNAL INPUT (RUN & JOG)

Also see descriptions of MULTI-FUNCTION INPUT TERMINALS, paragraph 5.18.

5.12 JOG REFERENCE

FREQ. CMD

n032 JOG

REF.

0

FREQ. CMD

n032 JOG

REF.

0

*

Or FWD

RUN

*

(Term. S1-S7) JOG

RUN

*

(Term. S1-S7) JOG

Advertising