29 copy function, Copy function -46 – Yaskawa V7 Drives User Manual

Page 98

Advertising
background image

5-46

The standard digital operator JVOP-140 of the V7 can be used to store (upload) parameters from one
drive, and copy (download) parameters to another drive. The copy function is not available on the
V74X. Parameters are stored in an EEPROM on the digital operator therefore no backup power supply
is necessary. The copy function can be used in most cases except the following.

(1)

Different drive types – The user may not copy parameters from a V7 to a J7 drive.

(2)

Different voltage class – The user may not copy parameters from a 230V drive to a 460V drive.

(3)

Different control mode – The user may not copy parameters from a drive operating in the Volts per

hertz mode (n002=0) to a drive in the Open loop vector mode (n002=1).

The following parameters are not copied when capacities are different.

5.29 COPY FUNCTION

Parameter No.

Parameter Name

Parameter No.

Parameter Name

n011 to n017

V/f Settings

n108

Motor Leakage Inductance

n036

Motor Rated Current

n109

Torque Boost

n080

Carrier Frequency

n110

Motor No-load Current

n105

Torque Comp Iron Loss

n140

Energy Saving Gain K2

n106

Motor Rated Slip

n107

Motor Line-to-line Resistance

n158

Motor Code (Energy Saving)

Parameters

n176, n177, n178 and n179 are not read into the digital operator during a read command.

n176: Parameter Copy Function Selection

Factory Setting: rdy

Setting

Description

rdy

Drive is ready to use Copy Function

rEd

Read (or upload) all parameters from the drive and store them in the Digital Operator

Cpy

Copy (or download) all parameters stored in the Digital Operator to the drive

uFy

Verify that parameters stored in the Digital Operator and the drive are the same

uA

Displays the voltage and kW rating of the drive whose parameters are stored in the
Digital Operator

Sno

Displays the software number of the drive whose parameters are stored in the Digital
Operator

n177:

P

arameter Copy Access Selection

The Copy Function can be enabled or disabled using parameter

n177 – parameters cannot be

uploaded when this parameter is disabled (

n177 = 0), preventing the accidental overwriting of

parameters stored in the Digital Operator.

If

n177 = 0 and an upload is attempted (n176 = rEd or Cpy), a "PrE" error message will blink on the

Digital Operator display – press DSPL or DATA/ENTER to clear the message.

Setting

Description

0

Reading Disabled

1

Reading Allowed

Factory Setting:

0