A1-2, Table a1-1. drive parameters - continued – Yaskawa V7 Drives User Manual

Page 122

Advertising
background image

A1-2

PARA-

SETTING RANGE

SETTING

FACTORY

USER

PARA.

METER

NAME

(AND UNITS)

INCREMENT

SETTING

SETTING

REF.

n018

Accel/Decel Time

0:

0.1

1 (sec)

0

5.2

Setting Unit

1:

0.01

n019

Acceleration Time 1 (Note 4)

0.00 to 600.0

0.01 (sec)

n020

Deceleration Time 1 (Note 4)

or

or

5.2

n021

Acceleration Time 2 (Note 4)

0.0 to 6000

0.1 (sec)

10.0

n022

Deceleration Time 2 (Note 4)

(Dependent on n018 setting)

0:

No S-curve

n023

S-curve Selection

1:

0.2 second

1

0

5.3

2:

0.5 second

3:

1.0 second

n024

Frequency Reference 1 (Note 4)

6.00

n025

Frequency Reference 2 (Note 4)

0.00

n026

Frequency Reference 3 (Note 4)

0.01 (Hz)

0.00

n027

Frequency Reference 4 (Note 4)

0.00 to 400.00

(< 100 Hz)

0.00

n028

Frequency Reference 5 (Note 4)

or

0.00

5.11

n029

Frequency Reference 6 (Note 4)

0.1 (Hz)

0.00

n030

Frequency Reference 7 (Note 4)

(>= 100 Hz)

0.00

n031

Frequency Reference 8 (Note 4)

0.00

n032

Jog Frequency Reference (Note 4)

6.00

5.12

n033

Frequency Reference Upper

0. to 110

1(%)

100

Limit

5.9

n034

Frequency Reference Lower

0. to 110

1(%)

0

Limit

0:

0.01 Hz (less than 100 Hz) / 0.1 Hz

n035

Digital Operator

1:

0.1%

1

0

5.30

Display Mode

2 - 39: rpm
40 - 3999: custom

0.1 to 49.5

n036

Motor Rated Current

(Up to 150% of drive rated current)

0.1 (A)

(Note 1)

5.25

0:

Short term rating

n037

Electronic Thermal Overload

1:

Standard rating

1

0

Protection (for OL1 fault)

2:

Disabled

5.25

n038

Electronic Thermal Overload

1 to 60

1 (min)

8

Protection Time Constant

0:

Operates only when drive is running

n039

Cooling Fan Operation

(continues operation for 1 minute after

1

0

Selection

drive is stopped)

1:

Operates with power applied to drive

n040

Motor Rotation

0:

Rotate C.C.W.

1

0

1:

Rotate C.W. (or opposite direction)

n041

Acceleration Time 3

0.00 to 600.00

0.01 (sec)

(Note 4)

n042

Deceleration Time 3

or

or

5.2

(Note 4)

n043

Acceleration Time 4

0.0 to 6000.0

0.1 (sec)

10.0

(Note 4)

n044

Deceleration Time 4

(Dependent on n018 setting)

(Note 4)

0:

Fwd / Rev command (3 wire control)

n050

Multi-function Input

[can only be set in n052]

1

1

Selection 1 (Terminal S1)

1:

Forward run (2 wire control)

(1)

2:

Reverse run (2 wire control)

3:

External Fault (N.O.)

n051

Multi-function Input

4:

External Fault (N.C.)

1

2

5.18

Selection 2 (Terminal S2)

5:

Fault Reset

(2)

6:

Multi-step speed ref. cmd. A

n052

Multi-function Input

7:

Multi-step speed ref. cmd. B

1

3

Selection 3 (Terminal S3)

8:

Multi-step speed ref. cmd. C

(0)

Table A1-1. Drive Parameters - Continued