A1-5, Table a1-1. drive parameters - continued – Yaskawa V7 Drives User Manual

Page 125

Advertising
background image

A1-5

PARA-

SETTING RANGE

SETTING

FACTORY

USER

PARA.

METER

NAME

(AND UNITS)

INCREMENT

SETTING

SETTING

REF.

0:

Detection Disabled

1:

Detect only at set frequency;
operation continues

2:

Detect only at set frequency;

n096

Overtorque Detection (OL3)

coast to stop

1

0

3:

Detect during all frequency conditions;
operation continues

4:

Detect during all frequency conditions;
coast to stop

5.20

Overtorque Detection

0:

Detected by output torque

1

0

n097

Selection (OL3)

1:

Detected by output current

n098

Overtorque Detection
Level (OL3)

30 to 200

1 (%)

160

n099

Overtorque Detection
Delay Time (OL3)

0.1 to 10.0

0.1 (sec)

0.1

n100

Up/Down Hold

0:

Disabled

Memory

1:

Enabled

1

0

5.10

n101

Speed Search
Deceleration Time

0.0 to 10.0

0.1 (sec)

2

5.18

n102

Speed Search Operation
Level

0 to 200%

1 (%)

150

5.18

n103

Torque Compensation Gain

0.0 to 2.5

0.1

1.0

(Note 4)

n104

Torque Compensation

5.26

Time Constant

0.0 to 25.5

0.1 (sec)

(Note 2)

n105

Torque Compensation

0.1 (W) or

Iron Loss

0.0 to 6550

1 (W)

(Note 1)

n106

Motor Rated Slip (Note 4)

0.0 to 20.0

0.1 (Hz)

(Note 1)

2.2, 5.22

n107

Motor Line-to-line

0.001 (ohm)

Resistance

0.000 to 65.50

(Note 1)

n108

Motor Leakage

0.01 (mH)

Inductance (Note 1)

0.00 to 655.0

or 0.1 (mH)

(Note 1)

n109

Torque Compensation

1 (%)

Limit

0 to 250

150

5.26

n110

Motor No-load Current

0 to 99

1 (%)

(Note 1)

2.2

n111

Slip Compensation Gain (Note 4)

0.0 to 2.5

0.1

(Note 2)

n112

Slip Compensation Primary

0.0 to 25.5

0.1 (sec)

(Note 2)

5.22

Delay Time

n113

Slip Compensation Selection

0:

Disabled

1

0

During Regeneration

1:

Enabled

0:

Disabled

n115

Stall Prevention Above Base

(level is based on setting of n094)

Speed During Run

1:

Enabled

1

0

(level at Fmax is n094 x 0.4)

0:

Follows acc/dec #1 (n019, n020)

5.23

or acc/dec #2 (n021, n022)

n116

Stall Prevention During Run,

Note: Multi-Function input selectable

1

0

Accel/Decel Time Select

1:

Follows acc/dec #2 (n021, n022)
always

0:

Undertorque detection disabled

1:

Detected during constant speed running.
Operation continues after detection

n117

Undertorque Detection

2:

Detected during constant speed running.

1

0

Select (UL3)

Operation stops during detection

3:

Detected during all frequency conditions.
Operation continues

4:

Detected during all frequency conditions.
coast to stop

5.34

0 to 200%

n118

Undertorque Detection

Inverter rated current = 100%; if n097 = 0

1(%)

0

Level (UL3)

(detection by torque); motor rated torque
becomes 100%

n119

Undertorque Detection

0.1 (sec)

Time (UL3)

0.1 to 10.0

0.1

n120

Frequency Reference 9 (Note 4)

0.00

n121

Frequency Reference 10 (Note 4)

0.01 (Hz)

0.00

n122

Frequency Reference 11 (Note 4)

(< 100 Hz)

0.00

n123

Frequency Reference 12 (Note 4)

0.00 to 400.00

or

0.00

5.11

n124

Frequency Reference 13 (Note 4)

0.1 (Hz)

0.00

n125

Frequency Reference 14 (Note 4)

(>= 100 Hz)

0.00

n126

Frequency Reference 15 (Note 4)

0.00

n127

Frequency Reference 16 (Note 4)

0.00

Table A1-1. Drive Parameters - Continued