Fault Display

Digital

RUN (Green)

Drive

Explanation

Causes and

Operator

ALARM (Red)

Status

Corrective Actions

UV2 (Control power

Cycle power.

supply fault)

If the fault remains.

Voltage fault of control

replace the drive.

power supply is detected.

OH (Cooling fin overheat)

• Excessive load

Temperature rise

• Improper V/f pattern

because of drive

setting

overload operation or

• Insufficient accel time

intake air temperature

if the fault occurs

rise.

during acceleration

• Intake air temperature

exceeding 122°F (50°C)

Check the following:
• Load size
• V/f pattern setting

(parameters n011 to n017)

• Intake air temperature.

OL1 (Motor overload)

• Check the load size or

Protective

Motor overload

V/f pattern setting

Operation.

protection operates by

(parameters n011 to n017)

Output is

built-in electronic thermal

• Set the motor rated

shut OFF

overload relay.

current shown on the

and motor

nameplate in parameter

coasts to

n036.

a stop.

OL2 (Drive overload)

• Check the load size or

Drive overload

V/f pattern setting

protection operates by

(parameters n011 to n017)

built-in electronic thermal

• Check the drive

overload relay.

capacity.

OL3 (Overtorque detection)

Check the driven

V/f mode: Drive output

machine and correct the

current exceeded the

cause of the fault, or

preset value in parameter

increase the value of

n098.

parameter n098 up to the

Open Loop Vector mode:

highest value allowed for

Motor current or torque

the machine.

exceeded the preset
value in parameters
n097 and n098.

When overtorque is
detected, drive performs
operation according to the
preset setting of parameter
n096.