1. To use 5.5/5.7 kw (7.5/10 Hp) Drives as open chassis, remove both top and bottom covers.

2. The clearances required at top/bottom and both sides are common in open chassis type

(IP00) and enclosed wall-mounted type (IP20).

3. For the external dimensions and mounting dimensions, refer to the “DIMENSIONS” section

of Appendix 5.

4. Allowable intake air temperature to the Drive:

Open chassis type:

-10°C to +50°C

Enclosed wall-mounted type:

-10°C to +40°C

5. Allow sufficient space for the sections at the upper and lower parts marked with * in order to

permit the flow of intake/exhaust air to/from the Drive.

Continued

1.3 PHYSICAL INSTALLATION

30mm

30mm

3.94 in.

(100mm)

3.94 in.

(100mm)

AIR

AIR