24 stopping method, Stopping method -35 – Yaskawa V7 Drives User Manual

Page 89

Advertising
background image

5-37

n005 : Stopping Method

Factory setting:

0

Range: 0 to 1

Selects the stopping method suitable for the application.

Setting

Description

0

Deceleration (ramp) to stop

1

Coast to stop

A.

Data

0 : Deceleration to Stop

Upon removal of the FWD (REV) Run
command, the motor decelerates at the
deceleration rate determined by the time
set in Decel Time 1 (

n020 ), and DC

injection braking is applied immediately
before stop. If the decel time is too short
or the load inertia is too large, an over-
voltage (OV) fault may occur on a stop
command — the decel time must be
increased.

B.

Data

1 : Coast to Stop

Upon removal of the FWD (REV) Run command, the motor coasts to rest.

5.24 STOPPING METHOD

Output Frequency

Run Command

ON

OFF

Decel Time 1
(

n020 )

Min. Output Frequency
(Frequency at DC Injection
Braking Start) (

n016 )

DC Injection Braking
Time at Stop (

n090 )

(Factory setting: 0.5 s)

Output Frequency

Run Command

ON

OFF

Drive output is shut OFF
when stop command is input

Advertising