34 undertorque detection, Undertorque detection -58 – Yaskawa V7 Drives User Manual

Page 110

Advertising
background image

5-58

Continued

For undertorque detection during accel or decel, set to " 3 " or " 4 ".

For continuous operation after undertorque detection, set to " 1 " or " 3 ". During detection, the Digital Operator
displays and “

UL3 ” alarm (blinking).

To stop the drive at an undertorque detection fault, set to " 2 " or " 4 ". At detection, the Digital Operator displays an
"

UL3 " fault.

To output an undertorque detection signal, set output terminal function selection (

n057, n058 or n059 ) to

" 8 " or " 9 ".

B.

n118 : Undertorque Detection Level

Factory setting:

10 %

Range: 0 to 200 %

This is the reference point for determining that an undertorque condition exists. Set as a percent of Drive rated
current or as a percent of motor rated torque.

C.

n119 : Undertorque Detection Time

Factory setting:

0.1 sec.

Range: 0.1 to 10.0 seconds

Determines how long an undertorque condition must exist before another event will occur, e.g. coast to stop,
multi-function output change of state, or

UL3 warning or fault display.

D.

n057 : Multi-function Output 1

Data

6 or 7 :

Overtorque

(terminals MA, MB & MC)

Detection

n058 : Multi-function Output 2

Data

8 or 9 :

Undertorque

(terminals P1 & PC)

Detection

n059 : Multi-function Output 3

(terminals P2 & PC)

A Form-C contact, or an open collector output, can be programmed to change states during an
overtorque/undertorque detection condition.

EXAMPLE OF OVERTORQUE DETECTION

n096 setting:

2

— Overtorque enabled, only at set frequency, coast to stop

n057 setting:

6 — Output contact programmed for overtorque detection

n096 setting:

110 %

— Level at which overtorque is sensed

n099 setting:

1.0 s

— Time delay before overtorque event occurs

Detection level
(

n098 )

Detection

110%

time

OUTPUT

100%

(

n099)

CURRENT/

TORQUE

0

100%

Coast

MOTOR

stop

SPEED

0

RUN

SIGNAL

FAULT

SIGNAL

CONTACT OUTPUT

(OVERTORQUE

DETECTION)

TERM. MA & MC)

Overtorque Detection Timing Diagram

5.34 UNDERTORQUE DETECTION