3 battery replacement, Rotation – Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Rotary Motors-Mechatrolink-II Communication Reference User Manual

Page 138

Advertising
background image

4 Operation

4.7.3 Battery Replacement

4-42

4.7.3 Battery Replacement

If the battery voltage drops to approximately 2.7 V or less, an absolute encoder battery error alarm (A.830) or

an absolute encoder battery error warning (A.930) will be displayed.

If this alarm or warning is displayed, replace the batteries using the following procedure.

Use Pn008.0 to set either an alarm (A.830) or a warning (A.930).

• If Pn008.0 is set to 0, alarm detection will be enabled for 4 seconds after the ALM signal outputs max. 5 sec-

onds when the control power is turned ON.

No battery-related alarm will be displayed even if the battery voltage drops below the specified value after

these 4 seconds.

• If Pn008.0 is set to 1, alarm detection will be always enabled after the ALM signal outputs max. 5 seconds

when the control power supply is turned ON.

Parameter

Meaning

When

Enabled

Classification

Pn008

n.

0

[Factory setting]

Outputs the alarm A.830 when the battery voltage
drops.

After restart

Setup

n.

1

Outputs the warning A.930 when the battery voltage
drops.

4 s

5 s max.

Warning A.930
(Pn008.0 = 1)

Alarm A.830
(Pn008.0 = 0)

ALM

OFF

Alarm status

Normal status

ON

Battery

voltage being

monitored

Battery voltage

being monitored

Control
power

Rotation

Advertising