4 ratings and specifications, 1 ratings – Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Rotary Motors-Mechatrolink-II Communication Reference User Manual

Page 28

Advertising
background image

1 Outline

1.4.1 Ratings

1-6

1.4 Ratings and Specifications

This section describes the ratings and specifications of SERVOPACKs and converters.

1.4.1 Ratings

Ratings of SERVOPACKs and converters are as shown below.

Three-phase 200 VAC

∗ Refer to 3.8 Selecting and Connecting a Regenerative Resistor Unit for details.

Three-phase 400 VAC

∗ Refer to 3.8 Selecting and Connecting a Regenerative Resistor Unit for details.

SERVOPACK Model

SGDV-

121H

161H

201H

Converter Model

SGDV-COA

2BAA

3GAA

3GAA

Continuous Output Current [Arms]

116

160

200

Instantaneous Max. Output Current [Arms]

240

340

460

Regenerative Resistor Unit

*

External

Main Circuit Power Supply

Three-phase 200 to 230 VAC, +10% to -15%, 50/60 Hz

Control Power Supply

Single-phase 200 to 230 VAC, +10% to -15%, 50/60 Hz

Overvoltage Category

III

SERVOPACK Model

SGDV-

750J

101J

131J

Converter Model

SGDV-COA

3ZDA

5EDA

5EDA

Continuous Output Current [Arms]

75

98

130

Instantaneous Max. Output Current [Arms]

170

230

340

Regenerative Resistor Unit

*

External

Main Circuit Power Supply

Three-phase 380 to 480 VAC, +10% to -15%, 50/60 Hz

Control Power Supply

24 VDC,

±15%

Overvoltage Category

III

Advertising