1 panel display, 1 status display, 2 alarm and warning display – Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Rotary Motors-Mechatrolink-II Communication Reference User Manual

Page 40: 3 hard wire base block display, 4 overtravel display, Mecha

Advertising
background image

2 Panel Display and Operation of Digital Operator

2.1.1 Status Display

2-2

2.1 Panel Display

The servo drive status can be checked on the panel display of the SERVOPACK.

Also, if an alarm or warning occurs, its alarm or warning number is displayed.

2.1.1 Status Display

The display shows the following status.

2.1.2 Alarm and Warning Display

If an alarm or warning occurs, the display will change in the following order.

Example: Alarm A.E60

2.1.3 Hard Wire Base Block Display

If a hard wire base block (HWBB) occurs, the display will change in the following order.

2.1.4 Overtravel Display

If overtravelling occurs, the display will change in the following order.

Display

Meaning

Rotation Detection (/TGON)
Lights if motor speed exceeds the value set in Pn502. (Factory setting: 20 min

-1

)

Baseblock
Lights for baseblock (Servomotor power OFF).

Reference Input
Lights when a reference is being input.

CONNECT
Lights during connection.

Status

Display

Unlit

Unlit

Unlit

Unlit

Unlit

MECHA

Status
Display

Unlit

Unlit

Unlit

Unlit

MECHA

Overtravel at forward rotation (P-OT)

Current
status

Current
status

Current
status

1

Overtravel at reverse rotation (N-OT)

2

Overtravel at forward/reverse rotation

3

MECHA

Advertising