background image

4.7 Absolute Encoders

4-49

4

Ope

rat

ion

(4) Transferring Alarm Contents

If an absolute encoder is used, the contents of alarms detected by the SERVOPACK are transmitted in serial

data to the host controller from the PAO output when the Turn Encoder Power Supply OFF command
(SENS_OFF) is received.

Note: The SENS_OFF command cannot be received while the servomotor power is ON.

Output example of alarm contents are as shown below.

Encoder power
supply OFF

Error detection

Encoder power supply ON

Incremental pulse

Serial Data

Enlarged view

Turn Encoder
Power Supply
OFF
(SENS_OFF)

Panel Display

PAO Output

Serial Data Format

Upper 2 digits

A

L

M

5

1

.

CR

" "

" "

" "

" "

" "

" " "

"

or

Overspeed