4.9 Safety Function

4-61

4

Ope

rat

ion

(2) Hard Wire Base Block (HWBB) State

The SERVOPACK will be in the following state if the HWBB function operates. If the /HWBB1 or /HWBB2

signal is OFF, the HWBB function will operate and the SERVOPACK will enter a hard wire baseblock
(HWBB) state.

/HWBB1
/HWBB2

M-

II

command

Status field
SVON

Motion
command, etc.

SV_OFF
command

1

0

0

1

SMON
command, etc.

IO monitor field
HBB

SERVOPACK
state

ON

(Normal operation)

(Normal operation)

OFF

(Motor current
shut-off request)

(Motor current shut-off request)

HWBB state

BB state

Operation

1

0

0

1

Motion
command, etc.

SMON
command, etc.

/HWBB1
/HWBB2

M-

II

command

Status field
SVON

IO monitor field
HBB

SERVOPACK
state

ON

OFF

HWBB state

Operation

The HWBB function operates after the servomotor power is turned OFF.

The HWBB function operates while the servomotor power is ON.