10 Appendix

10.1.2 Parameters

10-28

Pn824

2

Option Monitor 1 Selection

0000

Immediately

Setup

*1

0000H

Motor rotating speed

[1000000H/overspeed detection position]

0001H

Speed reference
[1000000H/overspeed detection position]

0002H

Torque [1000000H/max. torque]

0003H

Position error (lower 32 bits) [reference unit]

0004H

Position error (upper 32 bits) [reference unit]

0005H

System reserved

0006H

System reserved

000AH

Encoder count (lower 32 bits) [reference unit]

000BH

Encoder count (upper 32 bits) [reference unit]

000CH

FPG count (lower 32 bits) [reference unit]

000DH

FPG count (upper 32 bits) [reference unit]

0010H

Un000: Motor rotating speed [min

-1

]

0011H

Un001: Speed reference [min

-1

]

0012H

Un002: Torque reference [%]

0013H

Un003: Rotational angle 1 (encoder pulses from the
phase-C origin: decimal display)

0014H

Un004: Rotational angle 2 [deg]

0015H

Un005: Input signal monitor

0016H

Un006: Output signal monitor

0017H

Un007: Input position reference speed [min

-1

]

0018H

Un008: Position error [reference unit]

0019H

Un009: Accumulated load ratio [%]

001AH

Un00A: Regenerative load ratio [%]

001BH

Un00B: DB resistance consumption power [%]

001CH

Un00C: Input reference counter [reference unit]

001DH

Un00D: Feedback pulse counter [encoder pulse]

001EH

Un00E: Fully-closed loop feedback pulse counter
[external encoder resolution]

001FH

System reserved

0023H

Primary multi-turn data [Rev]

0024H

Primary incremental data [pulse]

0080H

Previous value of latched feedback position (LPOS)
[encoder pulse]

Pn825

2

Option Monitor 2 Selection

0000

Immediately

Setup

*1

0000H

to 0080H

Same as Option Monitor 1 Selection.

Pn827

2

Linear Deceleration Constant 1 for Stop-
ping

1 to 65535

10000

reference

unit/s

2

100

Immediately

*6

Setup

*1

Pn829

2

SVOFF Waiting Time (SVOFF at decel-
eration to stop)

0 to 65535

10 ms

0

Immediately

*6

Setup

*1

∗1. For details, refer to

Σ

-V Series User’s Manual MECHATROLINK-II Commands (No.: SIEP S800000 54).

∗6. Change the setting when the reference is stopped (DEN is set to 1), because the change will affect the output during

operation.

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classi-

fication

Reference

Section

Advertising