9.1 Alarm Displays

9-15

9

Trou

blesh

ooting

A.8A5:
External Encoder

Overspeed

The overspeed from the external
encoder occurred.

Check the maximum speed of the
external encoder.

Keep the external encoder below its
maximum speed.

A.8A6:
External Encoder

Overheated

The overheat from the external

encoder occurred.

Replace the external encoder.

A.b31:
Current Detection

Error 1

The current detection circuit for
phase U is faulty.

Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK may be

faulty. Replace the SERVOPACK.

A.b32:
Current Detection

Error 2

The current detection circuit for
phase V is faulty.

Turn the power supply OFF and

then ON again. If the alarm still
occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.

A.b33:
Current Detection

Error 3

The detection circuit for the cur-
rent is faulty.

Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.

The servomotor main circuit
cable is disconnected.

Check for disconnection of the ser-
vomotor main circuit cable.

Correct the servomotor wiring.

A.b6A:
MECHATROLINK

Communications ASIC

Error 1

SERVOPACK MECHA-
TROLINK communication sec-
tion fault.

Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.

A.b6b:
MECHATROLINK

Communications ASIC

Error 2

MECHATROLINK data recep-
tion error occurred due to noise
interference.

Take measures against noise. Check
the MECHATROLINK communi-
cations cable and FG wiring and
take measures such as adding ferrite
core on the MECHATROLINK
communications cable.

SERVOPACK MECHA-
TROLINK communication sec-
tion fault.

Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.

A.bF0:
System Alarm 0

A fault occurred in the SERVO-
PACK.

Turn the power supply OFF and

then ON again. If the alarm still
occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.

A.bF1:
System Alarm 1

A fault occurred in the SERVO-
PACK.

Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.

A.bF2:
System Alarm 2

A fault occurred in the SERVO-
PACK.

Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.

A.bF3

:

System Alarm 3

A fault occurred in the SERVO-
PACK.

Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.

A.bF4:
System Alarm 4

A fault occurred in the SERVO-
PACK.

Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.

(cont’d)

Alarm Number:

Alarm Name

(Alarm Description)

Cause

Investigative Actions

Corrective Actions