Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Rotary Motors-Mechatrolink-II Communication Reference User Manual

Page 336

Advertising
background image

9.2 Warning Displays

9-25

9

Trou

blesh

ooting

A.94D
Data Setting

Warning 4
(Parameter Size)

Parameter size set in
command is incorrect.

Refer to 9.3 Monitoring Communica-
tion Data on Occurrence of an Alarm

or Warning to determine which
command was the cause of the
warning.

Use the correct parameter size.

A.94E
Data Setting

Warning 5
(Latch mode
error)

Latch mode error is
detected.

Refer to 9.3 Monitoring Communica-
tion Data on Occurrence of an Alarm
or Warning
to determine which
command was the cause of the
warning.

Change the setting value of Pn850 or

the LT_MOD data for the
LTMOD_ON command sent by the
host controller to the proper value.

A.95A
Command

Warning 1
(Unsatisfying
Command)

Command sending con-
dition is not satisfied.

Refer to 9.3 Monitoring Communica-
tion Data on Occurrence of an Alarm
or Warning
to determine which

command was the cause of the
warning.

Send a command after command
sending condition is satisfied.

A.95B
Command

Warning 2
(Non-supported
Command)

SERVOPACK received
unsupported command.

Refer to 9.3 Monitoring Communica-
tion Data on Occurrence of an Alarm
or Warning
to determine which
command was the cause of the
warning.

Do not sent an unsupported command.

A.95D
Command

Warning 4
(Command Inter-
ference)

Command sending con-
dition for latch-related

commands is not satis-
fied.

Refer to 9.3 Monitoring Communica-
tion Data on Occurrence of an Alarm
or Warning
to determine which
command was the cause of the
warning.

Send a command after command

sending condition is satisfied.

A.95E
Command

Warning 5
(Subcommand
Disable)

Subcommand sending
condition is not satis-
fied.

Refer to 9.3 Monitoring Communica-
tion Data on Occurrence of an Alarm
or Warning
to determine which
command was the cause of the
warning.

Send a command after command
sending condition is satisfied.

A.95F
Command

Warning 6
(Undefined Com-
mand)

Undefined command

was sent.

Refer to 9.3 Monitoring Communica-
tion Data on Occurrence of an Alarm
or Warning
to determine which
command was the cause of the

warning.

Do not use an undefined command.

A.960
MECHATROLINK
Communications

Warning

MECHATROLINK
wiring is incorrect.

Confirm the wiring.

Correct the MECHATROLINK wir-
ing.

Or, connect a terminal to the terminal
station.

MECHATROLINK
data reception error
occurred due to noise
interference.

Confirm the installation conditions.

Take measures against noise. Check
the MECHATROLINK communica-
tions cable and FG wiring and take
measures such as adding ferrite core
on the MECHATROLINK communi-
cations cable.

A fault occurred in the
SERVOPACK.

A fault occurred in the SERVOPACK.
Replace the SERVOPACK.

(cont’d)

Warning Num-

ber: Warning

Name (Warning

Description)

Cause

Investigative Actions

Corrective Actions

Advertising