4.8 Other Output Signals

4-53

4

Ope

rat

ion

4.8 Other Output Signals

This section explains other output signals.

Use these signals according to the application needs, e.g., for machine protection.

4.8.1 Servo Alarm Output Signal (ALM)

This section describes signals that are output when the SERVOPACK detects errors and resetting methods.

(1) Servo Alarm Output Signal (ALM)

This signal is output when the SERVOPACK detects an error.

(2) Alarm Reset Method

If a servo alarm (ALM) occurs, use one of the following methods to reset the alarm after eliminating the cause

of the alarm.

Resetting Alarms by Sending Clear Warning or Alarm Command (ALM_CLR)

For details, refer to

Σ

-V Series User’s Manual, MECHATROLINK-II Commands (No.: SIEP S800000 54).

Resetting Alarms Using the Digital Operator

Press the ALARM RESET Key on the digital operator. For details, refer to

Σ

-V Series User’s Manual, Opera-

tion of Digital Operator (No.: SIEP S800000 55).

4.8.2 Warning Output Signal (/WARN)

This signal is for a warning issued before the occurrence of an alarm.
Refer to 9.2.1 List of Warnings.

(1) Signal Specifications

Note: Use parameter Pn50F.3 to allocate the /WARN signal for use. For details, refer to

3.4.2 Output Signal Alloca-

tions

.

Configure an external circuit so that this alarm output turns OFF the main circuit power
supply to the SERVOPACK and converter whenever an error occurs.

Type

Signal

Name

Connector

Pin Number

Setting

Meaning

Output

ALM

CN1-31, 32

ON (closed)

Normal status

OFF (open)

Alarm status

Be sure to eliminate the cause of the alarm before resetting it.
If the alarm is reset and operation continued without eliminating the cause of the alarm, it
may result in damage to the equipment or fire.

Type

Signal

Name

Connector Pin

Number

Setting

Meaning

Output

/WARN

Must be allocated

ON (closed)

Warning status

OFF (open)

Normal status