Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Rotary Motors-Mechatrolink-II Communication Reference User Manual

Page 315

Advertising
background image

9 Troubleshooting

9.1.1 List of Alarms

9-4

A.b31

Current Detection Error 1

The current detection circuit for phase U is faulty.

Gr.1

N/A

A.b32

Current Detection Error 2

The current detection circuit for phase V is faulty.

Gr.1

N/A

A.b33

Current Detection Error 3

The detection circuit for the current is faulty.

Gr.1

N/A

A.b6A

MECHATROLINK

Communications

ASIC Error 1

ASIC error occurred in the MECHATROLINK communications.

Gr.1

N/A

A.b6b

MECHATROLINK

Communications

ASIC Error 2

ASIC error occurred in the MECHATROLINK communications.

Gr.2

N/A

A.bF0

System Alarm 0

"Internal program error 0" of the SERVOPACK occurred.

Gr.1

N/A

A.bF1

System Alarm 1

"Internal program error 1" of the SERVOPACK occurred.

Gr.1

N/A

A.bF2

System Alarm 2

"Internal program error 2" of the SERVOPACK occurred.

Gr.1

N/A

A.bF3

System Alarm 3

"Internal program error 3" of the SERVOPACK occurred.

Gr.1

N/A

A.bF4

System Alarm 4

"Internal program error 4" of the SERVOPACK occurred.

Gr.1

N/A

A.C10

Servo Overrun Detected

The servomotor ran out of control.

Gr.1

Available

A.C80

Absolute Encoder Clear

Error and Multiturn Limit

Setting Error

The multiturn for the absolute encoder was not properly cleared or
set.

Gr.1

N/A

A.C90

Encoder Communications

Error

Communications between the SERVOPACK and the encoder is not

possible.

Gr.1

N/A

A.C91

Encoder Communications

Position Data Error

An encoder position data calculation error occurred.

Gr.1

N/A

A.C92

Encoder Communications

Timer Error

An error occurs in the communications timer between the encoder
and the SERVOPACK.

Gr.1

N/A

A.CA0

Encoder Parameter Error

Encoder parameters are faulty.

Gr.1

N/A

A.Cb0

Encoder Echoback Error

Contents of communications with encoder are incorrect.

Gr.1

N/A

A.CC0

Multiturn Limit

Disagreement

Different multiturn limits have been set in the encoder and the SER-
VOPACK.

Gr.1

N/A

A.CF1

Feedback Option Module

Communications Error

(Reception error)

Reception from the Feedback Option Module is faulty.

Gr.1

N/A

A.CF2

Feedback Option Module

Communications Error

(Timer stop)

Timer for communications with the Feedback Option Module is
faulty.

Gr.1

N/A

A.d00

Position Error Overflow

Position error exceeded the value of excessive position error alarm
level (Pn520) when the servomotor power is ON.

Gr.1

Available

A.d01

Position Error Overflow

Alarm at Servo ON

This alarm occurs if the servomotor power is turned ON when the
position error is greater than the set value of Pn526 while the servo-
motor power is OFF.

Gr.1

Available

A.d02

Position Error Overflow

Alarm by Speed Limit at

Servo ON

When the position errors remain in the error counter, Pn529 limits
the speed if the servomotor power is turned ON. If Pn529 limits the
speed in such a state, this alarm occurs when position references are
input and the number of position errors exceeds the value set for the
excessive position error alarm level (Pn520).

Gr.2

Available

A.d10

Motor-load Position Error

Overflow

During fully-closed loop control, the position error between motor
and load is excessive.

Gr.2

Available

A.E02

MECHATROLINK

Internal Synchronization

Error 1

Synchronization error during MECHATROLINK communications
with the SERVOPACK.

Gr.1

Available

A.E40

MECHATROLINK

Transmission Cycle

Setting Error

The setting of the MECHATROLINK transmission cycle is out of
the allowable range.

Gr.2

Available

(cont’d)

Alarm

Number

Alarm Name

Meaning

Servomotor

Stopping

Method

Alarm

Reset

Advertising