• Be sure to connect the servomotor’s built-in thermostat to the host controller or to the main circuit

magnetic contactor’s operation circuit.
Failure to observe this warning may result in injury, fire, or damage to the product.

• Usage Example 1:

In this example, the output signal from the thermostat is received by the host controller if the thermostat is
activated and the host controller turns OFF the servo.

• Usage Example 2:

In this example, the main circuit magnetic contactor’s operation circuit is activated or the output signal
from the thermostat is received by the host controller if the thermostat is activated and the main circuit
magnetic contactor is turned OFF.

• Installation, disassembly, or repair must be performed only by authorized personnel.

Failure to observe this warning may result in electric shock or injury.

• The person who designs a system using the safety function (Hard Wire Baseblock function) must

have full knowledge of the related safety standards and full understanding of the instructions in this

manual.
Failure to observe this warning may result in injury or damage to the product.

WARNING

Host controller

Servo OFF

ENC

M

Thermostat

Main circuit
magnetic
contactor

Main circuit

power supply

SERVOPACK

and

converter

M

Main circuit
magnetic
contactor

Main circuit

power supply

Main circuit

magnetic contactor

Host controller or main circuit
magnetic contactor’s operation circuit

SERVOPACK

and

converter

Thermostat

ENC