3 mechatrolink-ii function specifications, Rotation – Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Rotary Motors-Mechatrolink-II Communication Reference User Manual

Page 31

Advertising
background image

1.4 Ratings and Specifications

1-9

1

Outline

∗1. Speed regulation by load regulation is defined as follows:

∗2. Refer to 4.2.10 Velocity Control (VEL CTRL: 3CH) of

Σ

-V Series User’s Manual MECHATROLINK-II Commands

(No.: SIEP S800000 54) for details on the soft start function.

∗3. Set Pn001 to n.

2 if you do not use the dynamic brake.

∗4. Refer to 3.9 Selecting and Connecting a Dynamic Brake Unit for details on dynamic brake units.

∗5. Refer to 3.8 Selecting and Connecting a Regenerative Resistor Unit for details on regenerative resistor unit.

∗6. Implement risk assessment and confirm that the safety requirements of the machine have been met.

1.4.3 MECHATROLINK-II Function Specifications

The following table shows the specifications of MECHATROLINK-II.

Protective Function

Overcurrent, overvoltage, insufficient voltage, overload, regeneration error,
and so on.

Utility Function

Gain adjustment, alarm history, JOG operation, origin search, and so on.

Safety Function

Input

/HWBB1, /HWBB2: Baseblock signal for power module

Output

EDM1: Monitoring status of internal safety circuit (fixed output)

Standards

*6

(Application

pending)

EN 954 Category 3, IEC 61508 SIL2

Optional Module

Fully-closed module, safety module

(cont’d)

Speed regulation

=

No-load motor speed

Total load motor speed

Rated motor speed

× 100%

-

Rotation

Function

Specifications

MECHATROLINK-II

Communication

Communication Pro-

tocol

MECHATROLINK-II

Station Address

41H to 5FH (Max. number of stations: 30)
Can be selected by the combination of the rotary switch (S2)
and the DIP switch (S3).

Baud Rate

10 Mbps, 4 Mbps
Can be selected by the DIP switch (S3).

Transmission Cycle

250

μs, 0.5 ms to 4.0 ms (Multiples of 0.5 ms)

Number of Transmis-

sion Bytes

17 bytes per station or 32 bytes per station
Can be selected by the DIP switch (S3).

Reference Method

Control Method

Position, speed, or torque control with MECHATROLINK-

II communication

Reference Input

MECHATROLINK-I,MECHATROLINK-II commands
(sequence, motion, data setting/reference, monitoring, or
adjustment)

Advertising