3 Wiring and Connection

3.9.1 Selection

3-40

3.9 Selecting and Connecting a Dynamic Brake Unit

To use the dynamic brake (DB), externally connect a dynamic brake unit or dynamic brake resistor to the

SERVOPACK to process the dynamic braking energy.

Set Pn001 to n.

2 if you do not use the dynamic brake. In this case, it is not necessary to connect a

dynamic brake unit.

3.9.1 Selection

Use the following tables to select a dynamic brake unit or dynamic brake resistor.

(1) Using a Yaskawa Dynamic Brake Unit

(2) Using a Dynamic Brake Resistor from Another Company

To order a dynamic brake unit, contact the manufacturer directly.

Use the following dynamic brake contactors and surge absorption units.

∗ Use either a head-on or side-on main circuit surge absorption unit.

3.9.2 Selecting the Cable for the Dynamic Brake Unit

Use one of the following cables to connect the dynamic brake unit or dynamic brake contactor to CN115 on

the SERVOPACK.

Main Circuit

Power Supply

Voltage

SERVOPACK

Model:

SGDV-

Dynamic Brake

Unit Model

Resistance

Specifications

(Star Wiring

)

Dynamic Brake Contactor and

Surge Absorption Unit

Three-phase

200 V

121H, 161H, 201H

JUSP-DB02-E

180 W, 0.3

Ω × 3

Built into dynamic brake unit.

Three-phase

400 V

750J, 101J

JUSP-DB04-E

180 W, 0.8

Ω × 3

131J

JUSP-DB06-E

300 W, 0.8

Ω × 3

Main Circuit

Power Supply

Voltage

Model

Manufacturer

Required

Resistance

Three-phase
200 V

GR series

Japan Resistor Mfg. Co., Ltd.

0.3

Ω or greater

Three-phase
400 V

0.8

Ω or greater

Name

Model

Manufacturer

Contactor

SC-4-1/G
Coil: 24 VDC

Fuji Electric Co., Ltd.

Main circuit surge
absorption unit

*

Head-on type

SZ-ZM1

Side-on type

SZ-ZM2

Coil surge absorption unit

SZ-Z4

Cable Model

Cable

length

Cable End Processing on

Contact Coil End of Cable

Remarks

Manufacturer

JZSP-CVD00-1A5-E

1.5 m

Crimp terminals are attached
(M3.5).

Red: Pin 1 (DB24)
Black: Pin 3 (DBON)

Yaskawa Controls Co.,
Ltd.

JZSP-CVD00-03-E

3 m

Advertising