background image

3.1 Main Circuit Wiring

3-7

3

Wi

ring and

C

onne

ctio

n

For Three-phase, 400V

∗1. Use SERVOPACKs and converters in the specified combinations.

∗2. Use the crimp terminals that are recommended by Yaskawa or an equivalent.

Combination of SERVO-

PACK and Converter

*1

Terminal

Symbols

Screw Size

for Terminals

Tightening

Torque

(N m)

HIV Wire Size

in mm

2

(AWG)

Crimp Terminal

Model

(Made by J.S.T.

Mfg Co., Ltd.)

*2

SGDV-750J

SGDV-

COA3ZDA

SERVO-

PACK

P, N

M8

15.0

Bus bar attached

to the converter

U, V, W

M8

3.0

22 (4)

R22-8

DU, DV, DW

M6

3.0

3.5 (12)

3.5-6

M8

9.0 to 11.0

22 (4)

R22-8

Converter

P, N

M8

3.0

Bus bar attached

to the converter

L1, L2, L3

M8

3.0

22 (4)

R22-8

1, 2

M8

3.0 22

(4)

R22-8

CN101

(24 V, 0 V)

(Connector)

1.25 (16)

B1, B2

M8

3.0

8 (8)

R8-8

M8

9.0 to 11.0

22 (4)

R22-8

SGDV-101J

SGDV-

COA5EDA

SERVO-

PACK

P, N

M8

15.0

Bus bar attached

to the converter

U, V, W

M8

3.0

38 (1)

R38-8

DU, DV, DW

M6

3.0

3.5 (12)

3.5-6

M8

9.0 to 11.0

38 (1)

R38-8

Converter

P, N

M10

12 to 20

Bus bar attached

to the converter

L1, L2, L3

M10

12 to 20

38 (1)

R38-10

1, 2

M10

12 to 20

38 (1)

R38-10

CN101

(24 V, 0 V)

(Connector)

1.25 (16)

B1, B2

M10

12 to 20

8 (8)

R8-10

M8

9.0 to 11.0

38 (1)

R38-8

SGDV-131J

SGDV-

COA5EDA

SERVO-

PACK

P, N

M10

12 to 20

Bus bar attached

to the converter

U, V, W

M10

30.0

60 (2/0)

R60-10

DU, DV, DW

M6

3.0

3.5 (12)

3.5-6

M8

9.0 to 11.0

60 (2/0)

R60-8

Converter

P, CN

M10

12 to 20

Bus bar attached

to the converter

L1, L2, L3

M10

12 to 20

60 (2/0)

R60-10

1, 2

M10

12 to 20

60 (2/0)

R60-10

CN101

(24 V, 0 V)

(Connector)

1.25 (16)

B1, B2

M10

12 to 20

14 (6)

R14-10

M8

9.0 to 11.0

60 (2/0)

R60-8

Advertising