Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Rotary Motors-Mechatrolink-II Communication Reference User Manual

Page 58

Advertising
background image

3 Wiring and Connection

3.1.2 Main Circuit Wire

3-12

• For Three-phase, 400V

∗1. Use SERVOPACKs and converters in the specified combinations.

∗2. Use sleeves for the crimped section of the terminals.

∗3. A terminal kit includes the crimp terminals and sleeves required for one SERVOPACK or converter.

Combination of SERVO-

PACK and Converter

Terminal Sym-

bols

Crimp Terminal

Model (Made by

J.S.T. Mfg Co.,

Ltd.)

*1

Sleeve Model

(Made by Tokyo

Dip Co., Ltd.)

*2

Terminal Kit Model

*3

SGDV-750J

SGDV-

COA3ZDA

SERVOPACK

U, V, W

R38-8

TP-038 (black)

JZSP-CVT9-750J-E

DU, DV, DW

R5.5-6

TP-006 (black)

R38-8

Converter

L1, L2, L3

R38-8

TP-038 (black)

JZSP-CVT9-3ZD-E

1, 2

R38-8

TP-038 (white)

B1, B2

R8-8

TP-014 (white)

R38-8

SGDV-101J

SGDV-

COA5EDA

SERVOPACK

U, V, W

R60-8

TP-060 (black)

JZSP-CVT9-101J-E

DU, DV, DW

R5.5-6

TP-006 (black)

R60-8

Converter

L1, L2, L3

R38-10

TP-038 (black)

JZSP-CVT9-5ED1-E

1, 2

R38-10

TP-038 (white)

B1, B2

R8-10

TP-014 (white)

R38-8

SGDV-131J

SGDV-

COA5EDA

SERVOPACK

U, V, W

70-10

TP-080 (black)

JZSP-CVT9-131J-E

DU, DV, DW

R5.5-6

TP-006 (black)

70-8

Converter

L1, L2, L3

70-10

TP-080 (black)

JZSP-CVT9-5ED2-E

1, 2

70-10

TP-080 (white)

B1, B2

R22-10

TP-038 (white)

70-8

Advertising