10.1 List of Parameters

10-33

10

Ap

pend

ix

Pn883

2

Communications Cycle Setting Monitor
[x transmission cycle]
(for maintenance, read only)

0 to 32

0

Immediately

Setup

Pn88A

2

MECHATROLINK Receive Error
Counter Monitor (for maintenance, read

only)

0 to 65535

0

Immediately

Setup

Pn890 to

Pn89E

4

Command Data Monitor at Alarm/Warn-
ing Occurs
(for maintenance, read only)

0 to

FFFFFFFFH

0

Immediately

Setup

*1

Pn8A0 to

Pn8AE

4

Response Data Monitor at Alarm/Warn-
ing Occurs
(for maintenance, read only)

0 to

FFFFFFFFH

0

Immediately

Setup

*1

Pn900

2

Parameter Bank Number

0 to 16

0

After restart

Setup

*1

Pn901

2

Parameter Bank Member Number

0 to 15

0

After restart

Setup

*1

Pn902 to

Pn910

2

Parameter Bank Member Definition

0000H to

08FFH

0

After restart

Setup

*1

Pn920 to

Pn95F

2

Parameter Bank Data (nonvolatile mem-
ory save disabled)

0000H to

FFFFH

0

Immediately

Setup

*1

∗1. For details, refer to

Σ

-V Series User’s Manual MECHATROLINK-II Commands (No.: SIEP S800000 54).

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classi-

fication

Reference

Section