Chapter 8 Protocol Decoding

RIGOL

MSO1000Z/DS1000Z User’s Guide

8-11

Wherein, there are even number of 1 in the 8-bit data 01111101 and the check

bit should be 1; but the check bit detected on the TX is 0, thus check error

occurs.

Note:

Two error marks will be displayed when end frame error and check error

are detected at the same time.

(01111101, LSB)

Frame End Error

The check bit detected is 0

Frame Check Error