Chapter 5 To Trigger the Oscilloscope

RIGOL

MSO1000Z/DS1000Z User’s Guide

5-25

Delay Trigger (Option)

In delay trigger, you need to set signal source A and signal source B. The oscilloscope

triggers when the time difference (△T) between the specified edges of source A

(Edge A) and source B (Edge B) meets the preset time limit, as shown in the figure

below.

Note:

Edge A and Edge B must be neighbouring edges.

T

Source A

Source B

Edge A=

Edge B=

Figure 5-10 Delay Trigger

Trigger Type:

Press Type to open the trigger type list. Rotate

to select "Delay" and press down

. At this point, the trigger setting information is displayed at the upper right corner

of the screen.
For example,

. The trigger type is delay trigger; the current

trigger source is CH1; the trigger level is 0.00 V.

Source A:

Press SourceA to select CH1-CH4 as the trigger source of signal source A. For the

details, please refer to the introduction in "

Trigger Source". The current trigger

source is displayed at the upper right corner of the screen.

Note:

Select channel with signal input as trigger source to obtain stable trigger.

Edge A:

Press EdgeA to select the trigger edge type of signal source A in delay trigger. It can

be set to the rising edge or falling edge.

Source B:

Press SourceB to select CH1-CH4 as the trigger source of signal source B. For the

details, please refer to the introduction in "Trigger Source". The current trigger

source is displayed at the upper right corner of the screen.

Note:

Select channel with signal input as trigger source to obtain stable trigger.