background image

Chapter 14 Store and Recall

RIGOL

MSO1000Z/DS1000Z User’s Guide

14-3

4. Setups

Save the settings of the oscilloscope to internal or external memory in "*.stp"

format. The stored settings can be recalled.

5. CSV

Save the waveform data displayed on the screen or of the specified channels in

external memory in a single "*.csv" file. You can specify the file name and the

saving directory and save the corresponding parameter file (*.txt) under the

same directory using the same file name. This parameter file is the same as the

"Parameters" function. The recall of CSV and parameter files is not supported.

After selecting this type:
Press DataSrc to select "Screen" or "Memory". After selecting "Memory", press
Channel to select the desired channel (

Note:

Only channels currently enabled

can be selected).
Press Param to enable or disable the parameter save function.
Press Sequence to choose whether to add sequence numbers for the waveform
points in the CSV file. You can select "ON" or "OFF" and the default is "ON"
(namely add the sequence number).

6. Parameters

Save the parameters of the screen waveform to external memory in "*.txt"

format. The parameter storage contain the system information (such as the

software and hardware version numbers, time, date, etc) and the current

related setting information of the instrument (such as vertical, horizontal, trigger

and channel switching state, etc).