7. Delete

Press Delete to delete the current point from the waveform and connect the

remaining points using the current interpolation mode.

Note:

Point 1 cannot be deleted.

8. Apply

Press Apply to finish editing the current waveform.

9. Save

Press Save to enter the file store interface. Please refer to the introduction in

"Store and Recall" to save the current waveform file in ".arb" format in the

internal memory or external memory (you can overwrite the original file or save

the current waveform again).You can select the arbitrary waveforms in the

internal or external memory for output. For the details, refer to the introduction

in "To Select Waveform".

Modulation

The built-in signal generator of MSO1000Z/DS1000Z series oscilloscope supports

amplitude modulation (AM) and frequency modulation (FM). The modulated

waveform consists of the carrier waveform and modulating waveform. The carrier

waveform is the waveform output from the signal generator and the modulating

signal can be the built-in sine, square, ramp waveform or noise signal.

Press Src1Mod to open the source 1 modulation setting menu. Press Modulation

to turn on or off the modulation function. Press Mod.Type to set the modulation

type of the current signal to "AM" or "FM". Then, you can set the modulation

parameters according to the selected modulation type.