Site Configuration

5-52

Timers Hookups

Number of connected service-users with '10 mSec' device <10-100>

[70]:

The 10 msec task enables different modules to perform specific activities with a resolution of
10 msec. This is achieved by letting each module link itself to the 10 msec task. The number of
service users (modules) depends on the configuration and sometimes it may be necessary to
increase the value of this parameter (if the configuration includes more modules than the
default number specified here).

Number of '10 mSec' ticks passed before declaring error <3-10>

[4]:

The operating system is supposed to activate the 10 msec task every 10 msec. If it fails to
activate the task as many times as the number specified in this parameter (for example, 4
means if the system fails to activate the task during 40 msec), an error message is sent to the
Error Logger.

This is not a fatal error. If the system fails to activate the task this means that it is experiencing
an unusual burden (in which case it is advisable to locate the origin of the problem).

Number of connected service-users with '100 mSec' device <10-500>

[140]:

Same as the “Number of connected service-users with '10 mSec' device” parameter for the 100
msec task. Not applicable for IP Gateway.

Number of '100 mSec' ticks passed before declaring error <3-10> [4]:

Same as the “Number of '10 mSec' ticks passed before declaring error” parameter for the 100
msec task.

Number of connected service-users with '1 Sec' device <10-100> [20]:

Same as the “Number of connected service-users with '10 mSec' device” parameter for the 1
sec task. Not applicable for IP Gateway.

Number of '1 Sec' ticks passed before declaring error <2-5>

[2]:

Same as the “Number of '10 mSec' ticks passed before declaring error” parameter for the 1 sec
task.

Number of connected service-users with '1 Min' device <10-100> [16]:

Same as the “Number of connected service-users with '10 mSec' device” parameter for the 1
min task. Not applicable for IP Gateway.

Number of '1 Min' ticks passed before declaring error <2-4>

[2]:

Same as the “Number of '10 mSec' ticks passed before declaring error” parameter for the 1
min task.

Number of ’10 msec’ timers for ‘C’ applications <0-100>

[0]

The number of ‘C’ block 10 msec. timers that can be used. For details on how 10 msec. timers
in “C”’ block can be used, see ‘C’ Toolkit manual. Not applicable for IP Gateway.