Timers (10__ms , 100_ms , 1__sec , 1__min), 380 level = 0, Rs485 – Motorola 68P02958C00-B User Manual

Page 347

Advertising
background image

Software Diagnostics Output

C-55

TIMERS (10__MS , 100_MS , 1__SEC , 1__MIN)

## 380 LEVEL = 0

# of entries in the service table (actual)

: %% 1

Maximum # of entries in the service table

: %% 2

# of time units passed from last task running

: %% 3

The limit # of time units passed without activating task : %% 4

1. The number of timer services (in the specific Instance) currently in use.

2. The maximum number of timer services that can be used.

3. The number of time units (depending on the timer resolution) that have elapsed since the last

execution.

4. The maximum number of time units that will elapse without activating the instance, until an error

message reports instance timer delay.

RS485

## 520

Rs485 hardware/software last status :-
Internal software data (key)

(DATA)

: %% 1

Internal hardware registers

(IREG)

: %% 2

Internal hardware parameters

(IRAM)

: %% 3

Current channel port

(CHAN_PORT)

: %% 4

Channel status mode

(CHAN_MODE)

: %% 5

Channel driver lock

(CHAN_LOCK)

: %% 6

Channel signals

(CHAN_SIGNAL): %% 7

Channel access type

(CHAN_ACCESS): %%

Channel driver type

(CHAN_TYPE)

: %% 8

Channel control register

(PBCNT)

: %% 9

Channel direction register

(PBDDR)

: %% 10

Channel data register

(PBDAT)

: %% 11

Current reception empty buffers

: %% 12

Current reception ready buffers

: %% 13

Current transmission ready buffers

: %% 14

Current transmission empty buffers

: %% 15

1. Device-key address.

2. H-W registers address.

3. H-W parameters address.

4. Port number.

5. Configuration mode.

6. Channel access semaphore.

7. MTE signal on events that took place.

Advertising