Hardware Installation

3-4

Mechanical Installation

The IP Gateway unit can be supplied with the following two configurations:

Gateway with communication interface

In this configuration, the Gateway is mounted in an NEMA4 housing, suitable for wall
mounting and composed of the following:

Stand-alone Gateway unit

Radio unit applicable for the required frequency range and power, or alternatively, line
unit applicable for interfacing to dedicated or dial-up lines.

A 110V AC power supply + charger (produces +12V DC for the Gateway’s logic board
and charges the battery); a 220V AC power supply is available as an option.

12V DC battery rated for 5 Ah operation (10Ah battery is available as an option).

Figure 3-2: IP Gateway with Communication Interface