Error Messages

C-143

Error #282:

Unoperational Communication CHANNEL on: PORT #%% CONTROL=%%
STATUS=%%

The port is transferred to software mode. This message is displayed if CD is not
active.

Error #283:

Unoperational CHANNEL Internal LOOP on: PORT #%% CONTROL=%%
STATUS=%%

Incompatibility between the frame that was sent and received by the internal
loop.

Error #284:

Unoperational CHANNEL External LOOP on: PORT #%% CONTROL=%%
STATUS=%%

Incompatibility between the frame that was sent and received by the external
loop.

Error #285:

Unsuccessful CHANNEL Configuration on: PORT #%% COMMAND=%%
ANSWER=%%

Internal modem does not exist or illegal parameters were downloaded.

Error #286:

Uncontrollable CHANNEL Configuration on: PORT #%% COMMAND=%%
DATA=%%

Problem in the internal modem.

Error #287:

No response from internal DPSK modem on: port #%% command=%%
data=%%

Problem in the internal modem-piggyback plug in Port Type unit for Port 3.

Error #288:

An Incompatible piggyback was found.
The configuration was defined for Radio model: R%%
The installed piggyback ID is: %%
(see the table below for conversion)
The following table lists the available IDs:

Piggyback ID

Description

1

Spread Spectrum (Aironet) R202

2

Spread Spectrum (Aironet) R100

3

Spread Spectrum (Aironet) R202 AND DPSK interface

4

Spread Spectrum (Aironet) R100 AND DPSK interface

Other

Unknown, invalid or no piggiback

For Spread Spectrum radio only (MOSCAD-L only).

Error #289:

Could not program the spread spectrum (aironet) radio successfully. The
readback registers value was different from the written ones.

Piggyback cannot be programmed. Switch or fix piggyback.