Adding Terminal Server Ports

6-10

MOSCAD
8 Pin Connector
RJ 45 Connector

EQUINOX
8 Pin Connector
RJ 45 connector

1 (TXD)

6 (RxD)

2 (RXD)

4 (TxD)

3 (CTS)

7 (DTR)

4 (GND)

3 (GND)

5 (CD)

8 (RTS)

6 (RTS)

2 (DCD)

(*) 7 (12V)

N.C

8 (DTR)

1 (CTS)

Configuration

General notes:

The commands to be entered were given under the assumption that the ELS16 is
performing a ‘self boot’. In case of a boot server, please refer to EQUINOX
documentation.

Commands can be typed in lower case or in upper case letters.

After each command, press the <Return>key. If the command was entered legally, then
ELS16 prompts: “Local>“

N represents a port number. It can be any number in the range of 1 to16

t represents a value in seconds between 10 and 180

a and m represents a number in the range of 0..255

SOCKET_NUMBER represent a TCP socket. Each port must have a deferent TCP
socket number, which must be greater than 2001 or equal.

SERVICE_NAME is a string given to a service as its’ name.

The first command to be entered will allow the user access to EQUINOX configuration.
The default password is SYSTEM.

After attaching a console terminal (usually at port 1), type in the following commands.

SET PRIV < return>

SYSTEM <return>