High Performance Two Port 10/100 Managed Ethernet Switch with 32-Bit Non-PCI CPU Interface

Datasheet

SMSC LAN9312

267

Revision 1.4 (08-19-08)

DATASHEET

14.2.9.7

Free Running 25MHz Counter Register (FREE_RUN)

This read-only register reflects the current value of the free-running 25MHz counter. Refer to

Section

12.2, "Free-Running Clock," on page 161

for additional information.

Offset:

09Ch

Size:

32 bits

BITS

DESCRIPTION

TYPE

DEFAULT

31:0

Free Running Counter (FR_CNT)
This field reflects the current value of the free-running 32-bit counter. At
reset, the counter starts at zero and is incremented by one every 25MHz
cycle. When the maximum count has been reached, the counter will rollover
to zero and continue counting.

Note:

The free running counter can take up to 160nS to clear after a reset
event.

RO

00000000h