DATASHEET

14.4.2.2

Port x PHY Basic Status Register (PHY_BASIC_STATUS_x)

This register is used to monitor the status of the Port x PHY.

Index (decimal):

1

Size:

16 bits

BITS

DESCRIPTION

TYPE

DEFAULT

15

100BASE-T4
This bit displays the status of 100BASE-T4 compatibility.

0: PHY not able to perform 100BASE-T4
1: PHY able to perform 100BASE-T4

RO

0b

Note 14.52

14

100BASE-X Full Duplex
This bit displays the status of 100BASE-X full duplex compatibility.

0: PHY not able to perform 100BASE-X full duplex
1: PHY able to perform 100BASE-X full duplex

RO

1b

13

100BASE-X Half Duplex
This bit displays the status of 100BASE-X half duplex compatibility.

0: PHY not able to perform 100BASE-X half duplex
1: PHY able to perform 100BASE-X half duplex

RO

1b

12

10BASE-T Full Duplex
This bit displays the status of 10BASE-T full duplex compatibility.

0: PHY not able to perform 10BASE-T full duplex
1: PHY able to perform 10BASE-T full duplex

RO

1b

11

10BASE-T Half Duplex
This bit displays the status of 10BASE-T half duplex compatibility.

0: PHY not able to perform 10BASE-T half duplex
1: PHY able to perform 10BASE-T half duplex

RO

1b

10

100BASE-T2 Full Duplex
This bit displays the status of 100BASE-T2 full duplex compatibility.

0: PHY not able to perform 100BASE-T2 full duplex
1: PHY able to perform 100BASE-T2 full duplex

RO

0b

Note 14.52

9

100BASE-T2 Half Duplex
This bit displays the status of 100BASE-T2 half duplex compatibility.

0: PHY not able to perform 100BASE-T2 half duplex
1: PHY able to perform 100BASE-T2 half duplex

RO

0b

Note 14.52

8:6

RESERVED

RO

-

5

Auto-Negotiation Complete
This bit indicates the status of the Auto-Negotiation process.

0: Auto-Negotiation process not completed
1: Auto-Negotiation process completed

RO

0b

4

Remote Fault
This bit indicates if a remote fault condition has been detected.

0: No remote fault condition detected
1: Remote fault condition detected

RO/LH

0b