Section 14.5.2.11, Datasheet – SMSC LAN9312 User Manual

Page 332

Advertising
background image

High Performance Two Port 10/100 Managed Ethernet Switch with 32-Bit Non-PCI CPU Interface

Datasheet

Revision 1.4 (08-19-08)

332

SMSC LAN9312

DATASHEET

14.5.2.11

Port x MAC Receive OK Count Register (MAC_RX_PKTOK_CNT_x)

This register provides a counter of received packets that are or proper length and are free of errors.
The counter is cleared upon being read.

Note:

A bad packet is one that has a FCS or Symbol error.

Register #:

Port0: 0418h

Size:

32 bits

Port1: 0818h
Port2: 0C18h

BITS

DESCRIPTION

TYPE

DEFAULT

31:0

RX OK
Count of packets that are of proper length and are free of errors.

Note:

This counter will stop at its maximum value of FFFF_FFFFh.
Minimum rollover time at 100Mbps is approximately 481 hours.

RC

00000000h